Low temperature range down to -110 °C

For the heating and cooling of process-related systems in the low temperature range down to -110°C, heat transfer fluids must have an outstanding viscosity at low temperatures. This enables good pumpability and problem-free system start-up.

 

back to overview

Areas of application:

  • Combined heating and cooling processes for endothermic and exothermic reactions in a reactor (e.g. production of fine chemicals)
  • Pharmaceutical industry
  • Climatic chambers
  • Applications with widely varying temperatures in a wide range, e.g. batch reaction processes in small industrial or pilot plants

Our heat transfer media are suitable for this temperature range:

FRAGOLTHERM® F-LT
FRAGOLTHERM® F-LT

FRAGOLTHERM® F-LT

Dichte 20 °C:
Density 20 °C:
866 kg/m³
Kin. Viskosität 40 °C:
Kin. viscosity 40 °C:
0,81 mm²/s
Pourpoint:
Pour Point:
-75 °C
Untere Einsatzgrenze:
Minimal operating temperature:
-73 °C
Vorlauftemperatur max.:
Bulk temperature max.:
315 °C
Filmtemperatur max.:
Film temperature max.:
340 °C
Siedebeginn:
Boiling Point:
181 °C
Flammpunkt:
Flash Point:
>58 °C
Wassergefährdungsklasse:
Water hazard classification:
2
Freigaben:
Approval:
-
-73 °C
315 °C
FRAGOLTHERM® F-12
FRAGOLTHERM® F-12

FRAGOLTHERM® F-12

Dichte 20 °C:
Density 20 °C:
763 kg/m³
Kin. Viskosität 40 °C:
Kin. viscosity 40 °C:
1,18 mm²/s
Pourpoint:
Pour Point:
-98 °C
Untere Einsatzgrenze:
Minimal operating temperature:
-85 °C
Vorlauftemperatur max.:
Bulk temperature max.:
230 °C
Filmtemperatur max.:
Film temperature max.:
245 °C
Siedebeginn:
Boiling Point:
194 °C
Flammpunkt:
Flash Point:
62 °C
Wassergefährdungsklasse:
Water hazard classification:
1
Freigaben:
Approval:
HT1-Freigabe, FDA 21 CFR
-85 °C
230 °C
FRAGOLTHERM® X-T15
FRAGOLTHERM® X-T15

FRAGOLTHERM® X-T15

Dichte 20 °C:
Density 20 °C:
904 kg/m³
Kin. Viskosität 40 °C:
Kin. viscosity 40 °C:
1,50 mm²/s
Pourpoint:
Pour Point:
<-120 °C
Untere Einsatzgrenze:
Minimal operating temperature:
-80 °C
Vorlauftemperatur max.:
Bulk temperature max.:
270 °C
Filmtemperatur max.:
Film temperature max.:
290 °C
Siedebeginn:
Boiling Point:
>225 °C
Flammpunkt:
Flash Point:
>82 °C
Wassergefährdungsklasse:
Water hazard classification:
1
Freigaben:
Approval:
-
-80 °C
270 °C
FRAGOLTHERM® X-T12
FRAGOLTHERM® X-T12

FRAGOLTHERM® X-T12

Dichte 20 °C:
Density 20 °C:
850 kg/m³
Kin. Viskosität 40 °C:
Kin. viscosity 40 °C:
1,20 mm²/s
Pourpoint:
Pour Point:
<-111 °C
Untere Einsatzgrenze:
Minimal operating temperature:
-105 °C
Vorlauftemperatur max.:
Bulk temperature max.:
260 °C
Filmtemperatur max.:
Film temperature max.:
290 °C
Siedebeginn:
Boiling Point:
>190 °C
Flammpunkt:
Flash Point:
64 °C
Wassergefährdungsklasse:
Water hazard classification:
1
Freigaben:
Approval:
-
-105 °C
260 °C
FRAGOLTHERM® X-T9-A
FRAGOLTHERM® X-T9-A

FRAGOLTHERM® X-T9-A

Dichte 20 °C:
Density 20 °C:
845 kg/m³
Kin. Viskosität 40 °C:
Kin. viscosity 40 °C:
0,96 mm²/s
Pourpoint:
Pour Point:
<-112 °C
Untere Einsatzgrenze:
Minimal operating temperature:
-110 °C
Vorlauftemperatur max.:
Bulk temperature max.:
200 °C
Filmtemperatur max.:
Film temperature max.:
220 °C
Siedebeginn:
Boiling Point:
-
Flammpunkt:
Flash Point:
>32°C
Wassergefährdungsklasse:
Water hazard classification:
1
Freigaben:
Approval:
-
-110 °C
200 °C
× We want to help!×

We look forward to your inquiry

Heat Transfer Fluids

Phone: +49 (0)208-300-02-50
Fax: +49 (0)208-300-02-33
Email: htffragol.de

Lubricants

Phone: +49 (0)208-300-02-40
Fax: +49 (0)208-300-02-77
Email: lubesfragol.de

Office

Phone: +49 (0)208-300-02-25
Fax: +49 (0)208-300-02-31
Email: rewefragol.de

Please use our contact form

For emergencies outside office hours:
+49 (0)208-300-02-99.